2015 Greenthaw Dryair 300GTS Ground Heater + Concrete Curer w/ Generator
2015 Greenthaw Dryair 300GTS
Hours: 4,434
Pintle Hitch
301k BTU Heater
Fuel: Diesel Fuel/ #1 or #2 Heating Oil
Burner: Single stage
Input capacity: 301,000 BTU
Output max capacity: 228,000 BTU
Fuel Consumption (100% run time) 2.15 GPH
Maximum thawing capacity: 6,000 sq. ft
Maximum Curing Area: 12,040 sq. ft
Operating temp: 195 degrees Fahrenheit
Heating capacity – area: 433,154 cu. ft
Heat transfer fluid: nontoxic propylene glycol
Operating pressure: 35 PSI
Flow: 965 GPH
Power Hose Reel
Onboard Hose max: 3,000′
Fuel Capacity: 150 gallons
Onboard 6.5KW Diesel gl7000 Kubota Generator
-Fully Enclosed
-Powers machine to make it useable on any jobsite
-Phase: Single
-120/240
No need to bring the Greenthaw into a heated shop before it goes out on jobsite! The preheater allows the unit to start and run-in sub-40-degree conditions!
Unit was just serviced and greased an ready to work!
2015 Greenthaw Dryair 300GTS Ground Heater + Concrete Curer w/ Generator
2015 Greenthaw Dryair 300GTS
Hours: 4,807
Pintle Hitch
301k BTU Heater
Fuel: Diesel Fuel/ #1 or #2 Heating Oil
Burner: Single stage
Input capacity: 301,000 BTU
Output max capacity: 228,000 BTU
Fuel Consumption (100% run time) 2.15 GPH
Maximum thawing capacity: 6,000 sq. ft
Maximum Curing Area: 12,040 sq. ft
Operating temp: 195 degrees Fahrenheit
Heating capacity – area: 433,154 cu. ft
Heat transfer fluid: nontoxic propylene glycol
Operating pressure: 35 PSI
Flow: 965 GPH
Power Hose Reel
Onboard Hose max: 3,000′
Fuel Capacity: 150 gallons
Onboard 6.5KW Diesel gl7000 Kubota Generator
-Fully Enclosed
-Powers machine to make it useable on any jobsite
-Phase: Single
-120/240
No need to bring the Greenthaw in to a heated shop before it goes out on jobsite! The preheater allows the unit to start and run in sub 40 degree conditions!
Unit was just serviced and greased an ready to work!
2013 Campo Ecoblaze Blaze Cube 1100 Indirect Fired Enclosed Self-Contained Mobile Construction Heater
2013 Campo Ecoblaze Blaze Cube 1100
Powered by onboard Kubota Diesel Generator
NO.1, NO.2, Kerosene, furnace oil fired
IDF Heater (Indirect Fired Heater)
Hours: 6,027
2x 510,000 BTU heaters
4x 12” Outlets
Self-Contained and enclosed
Unit was just serviced and ready to go to work!
2015 Mosebach HBX150 150kw Construction Portable Electric Heater
2015 Mosebach HBX150
150kw Portable Heater
480V 3 Phase
50kW Steps
Up to 512k BTU/H
550lbs
5,500 CFM
Over Temp Protection
Restricted Airflow Protection
Voltage Protection
Tip Fault
2013 Spaulding R.M.V. Hot Patcher Hot Box Trailer
4 Ton capacity
Dual Axle
Diesel Fired
-Unit is missing Burner and batteries
Unit is in Good shape
2014 MAC 800G Indirect Fired Enclosed Self-Contained Mobile Construction Heater
2014 MAC 800G
Powered by Isuzu Diesel
Diesel Fired
Hours: 4,095
800,000 BTU
2x 11” Outlet
2x 11″ Ducting included
Self-Contained and fully enclosed
IDF Heater (Indirect Fired Heater)
Air output volume: 3,900 Cubic Ft per minute
Unit is fully function and ready to go to work!
2010 Dryair Greenthaw 600GTS Ground Heater w/ Generator
2010 Dryair 600GTS
Hours: 2,218
Diesel Fired
Pintle Hitch
Onboard 7KW Kubota Diesel Powered Whisper Watt Generator
-Fully Enclosed
-Powers machine to make it useable on any jobsite
-Phase: 1
-120/240
620k BTU Heater
4,000’ of hose
-Power Reel (In and out)
THAW AREA – 6,000 ft² (std), 11,200 ft² (w/acc)
CURE AREA – 8,000 ft² (std), 25,000 ft² (w/acc)
The large 620,000 BTU heater provides you with ample BTU’s for ground thaw, concrete cure & space or fluid heating applications
Patented Flow Reverser – Eliminates hot and cold zones in the thaw pattern
Reduces time & fuel costs by up to 50%
Consistent curing temperatures across the entire slab means the whole slab cures at the same rate
Patented Combustion Environment Control System preheats the fuel and air used for combustion
No need to bring it in to a heated shop before it goes out on the job. The preheater allows the unit to start & run even in sub 40 degree conditions
Industry leading multi-loop ground thaw set-up for job site flexibility and optimum fluid circulation & heat transfer
Manifold System allows for fan coils or heat exchangers to plug in for space heating or fluid heating
Unit is fully functional and ready to go to work!
Recent Comments