2012 Thawzall H250SL Heatzone Ground Heater W/ Generator

2012-THAWZALL-H250SL-HEATZONE-GROUND-HEATER W/-GENERATOR-Concrete-Curing-Ground-Thawing-Excavation-Work

2012 Thawzall H250SL Heatzone Ground Heater W/ Generator

2012 Thawzall H250SL

Diesel Engine Powered/Genset

Hour meter Reads: 12,298 Hours

280k BTU Heater

THAW frozen ground sq 3,000’-6,000’ Max

CURE concrete sq 6,000’ sq with accessories 18,000’ sq Max

FROST prevention sq 9,000’ sq with accessories 27,000’ sq Max

HEAT buildings

Operating Range °F 70-200

Operating Pressure psi 1-5

Fuel Consumption (max) gph 1.75

Run Time days 3+

Pump Capacity gpm/gph 30/1800

THAWZALL TCH250 DIMENSIONS & CAPACITIES:

L x W x H  170” x 84” x 97”

Weight w/fuel & fluid 5,600lbs

Fuel Capacity: 160 Gallons

HTF (Heat Transfer Fluid) 122 Gallons

THAWZALL TCH250 MISC SPECIFICATIONS:

One – 1/2 hp Pump Closed Loop Centrifugal

Max Hose Length Capacity: (5 zones x 600’) 3,000’

Electrical, GFI 1) 20 amp x 120 vac

HTF Pumpability °F -80 °

Fuel Winter blend diesel or #1 fuel oil

Pintle Hitch

Unit has been serviced and greased!

2008 Tempair Hydro-Thaw HTHW-2000G Ground Heater w/ Generator

2008-Tempair-Hydro-Thaw-Hydronic-HTHW-2000G Ground-Heater-Concrete-Curing-Ground-Thawing-Excavation-Work

2008 Tempair Hydro-Thaw Hydronic HTHW-2000G Ground Heater

2008 Tempair Hydro-Thaw HTHW-2000G

Hour meter reads: 7,638 Hours

Diesel Engine Powered/Genset

Weight: 7,860lbs (8,910 Fueled)

BTU/HR: 280,000

BTU/HR output: 231,000

Heating Circuits: 2

On Board Fuel Capacity: 150 Gallons

Two Reel System w/ Power Feed and Out

Pintle Hitch

Unit has been Serviced and Greased!

2015 Dryair Greenthaw 300GTS Ground Heater w/ Generator

2015-DRYAIR-GREENTHAW-300GTS-GROUND-HEATER W/-GENERATOR-Concrete-Curing-Ground-Thawing-Excavation-Work

2015 Dryair Greenthaw 300GTS Ground Heater w/ Generator
2015 Greenthaw Dryair 300GTS
Hours: 2,849
Pintle Hitch
301k BTU Heater
Fuel: Diesel Fuel/ #1 or #2 Heating Oil
Burner: Single stage
Input capacity: 301,000 BTU
Output max capacity: 228,000 BTU
Fuel Consumption (100% run time) 2.15 GPH
Maximum thawing capacity: 6,000 sq. ft
Maximum Curing Area: 12,040 sq. ft
Operating temp: 195 degrees Fahrenheit
Heating capacity – area: 433,154 cu. ft
Heat transfer fluid: nontoxic propylene glycol
Operating pressure: 35 PSI
Flow: 965 GPH
Power Hose Reel
Onboard Hose max: 3,000′
Fuel Capacity: 150 gallons
Onboard 6.5KW Diesel gl7000 Kubota Generator
-Fully Enclosed
-Powers machine to make it useable on any jobsite
-Phase: Single
-120/240
No need to bring the Greenthaw in to a heated shop before it goes out on jobsite! The preheater allows the unit to start and run in sub 40 degree conditions!
Unit was just serviced and greased an ready to work!

2011 Dryair Greenthaw 600GTS Ground Heater w/ Generator

2011-DRYAIR-GREENTHAW-600GTS-GROUND-HEATER W/-GENERATOR-Concrete-Curing-Ground-Thawing-Excavation-Work

2011 Dryair Greenthaw 600GTS Ground Heater w/ Generator

2011 Dryair 600GTS

Genset Hour Meter Reads: 314 Hours

Diesel Fired

2” Ball

Onboard 7KW Kubota Diesel Powered Whisper Watt Generator

-Fully Enclosed

-Powers machine to make it useable on any jobsite

-Phase: 1

-120/240

620k BTU Heater

Can Carry up to 4,000’ of Hose

-Power Reel (In and out)

THAW AREA – 6,000 ft² (std), 11,200 ft² (w/acc)

CURE AREA – 8,000 ft² (std), 25,000 ft² (w/acc)

The large 620,000 BTU heater provides you with ample BTU’s for ground thaw, concrete cure & space or fluid heating applications

Patented Flow Reverser  – Eliminates hot and cold zones in the thaw pattern

Reduces time & fuel costs by up to 50%

Consistent curing temperatures across the entire slab means the whole slab cures at the same rate

Patented Combustion Environment Control System preheats the fuel and air used for combustion

No need to bring it in to a heated shop before it goes out on the job.  The preheater allows the unit to start & run even in sub 40 degree conditions

Industry leading multi-loop ground thaw set-up for job site flexibility and optimum fluid circulation & heat transfer

Manifold System allows for fan coils or heat exchangers to plug in for space heating or fluid heating

Unit is fully functional and ready to go to work!

2011 Dryair Greenthaw 600GTS Ground Heater w/ Generator

2011-DRYAIR-GREENTHAW-600GTS-GROUND-HEATER W/-GENERATOR-Concrete-Curing-Ground-Thawing-Excavation-Work

2011 Dryair Greenthaw 600GTS Ground Heater w/ Generator

2011 Dryair 600GTS

Hours: 8,698

Diesel Fired

2” Ball

Onboard 7KW Kubota Diesel Powered Whisper Watt Generator

-Fully Enclosed

-Powers machine to make it useable on any jobsite

-Phase: 1

-120/240

620k BTU Heater

Can Carry up to 4,000’ of Hose

-Power Reel (In and out)

THAW AREA – 6,000 ft² (std), 11,200 ft² (w/acc)

CURE AREA – 8,000 ft² (std), 25,000 ft² (w/acc)

The large 620,000 BTU heater provides you with ample BTU’s for ground thaw, concrete cure & space or fluid heating applications

Patented Flow Reverser  – Eliminates hot and cold zones in the thaw pattern

Reduces time & fuel costs by up to 50%

Consistent curing temperatures across the entire slab means the whole slab cures at the same rate

Patented Combustion Environment Control System preheats the fuel and air used for combustion

No need to bring it in to a heated shop before it goes out on the job.  The preheater allows the unit to start & run even in sub 40 degree conditions

Industry leading multi-loop ground thaw set-up for job site flexibility and optimum fluid circulation & heat transfer

Manifold System allows for fan coils or heat exchangers to plug in for space heating or fluid heating

Unit is fully functional and ready to go to work!

2015 Greenthaw Dryair 300GTS Ground Heater + Concrete Curer w/ Generator

2015-Greenthaw-Dryair-300GTS-Ground-Heater-Concrete-Curing-Heater-Towable-Jobsite-Machine

2015 Greenthaw Dryair 300GTS Ground Heater + Concrete Curer w/ Generator

2015 Greenthaw Dryair 300GTS

Hours: 4,434

Pintle Hitch

301k BTU Heater

Fuel: Diesel Fuel/ #1 or #2 Heating Oil

Burner: Single stage

Input capacity: 301,000 BTU

Output max capacity: 228,000 BTU

Fuel Consumption (100% run time) 2.15 GPH

Maximum thawing capacity: 6,000 sq. ft

Maximum Curing Area: 12,040 sq. ft

Operating temp: 195 degrees Fahrenheit

Heating capacity – area: 433,154 cu. ft

Heat transfer fluid: nontoxic propylene glycol

Operating pressure: 35 PSI

Flow: 965 GPH

Power Hose Reel

Onboard Hose max: 3,000′

Fuel Capacity: 150 gallons

Onboard 6.5KW Diesel gl7000 Kubota Generator

-Fully Enclosed

-Powers machine to make it useable on any jobsite

-Phase: Single

-120/240

No need to bring the Greenthaw into a heated shop before it goes out on jobsite! The preheater allows the unit to start and run-in sub-40-degree conditions!

Unit was just serviced and greased an ready to work!

2015 Greenthaw Dryair 300GTS Ground Heater + Concrete Curer w/ Generator

2015-Greenthaw-Dryair-300GTS-Ground-Heater-Concrete-Curing-Heater-Towable-Jobsite-Machine

2015 Greenthaw Dryair 300GTS Ground Heater + Concrete Curer w/ Generator

2015 Greenthaw Dryair 300GTS

Hours: 4,807

Pintle Hitch

301k BTU Heater

Fuel: Diesel Fuel/ #1 or #2 Heating Oil

Burner: Single stage

Input capacity: 301,000 BTU

Output max capacity: 228,000 BTU

Fuel Consumption (100% run time) 2.15 GPH

Maximum thawing capacity: 6,000 sq. ft

Maximum Curing Area: 12,040 sq. ft

Operating temp: 195 degrees Fahrenheit

Heating capacity – area: 433,154 cu. ft

Heat transfer fluid: nontoxic propylene glycol

Operating pressure: 35 PSI

Flow: 965 GPH

Power Hose Reel

Onboard Hose max: 3,000′

Fuel Capacity: 150 gallons

Onboard 6.5KW Diesel gl7000 Kubota Generator

-Fully Enclosed

-Powers machine to make it useable on any jobsite

-Phase: Single

-120/240

No need to bring the Greenthaw in to a heated shop before it goes out on jobsite! The preheater allows the unit to start and run in sub 40 degree conditions!

Unit was just serviced and greased an ready to work!

2013 Macgill-Ross MAC6000 Ground Heater w/ Generator

2013-Macgill-Ross-MAC-MAC6000-Ground-Curing-Construction-Heating-Concrete-Curing-Ground-Heater-Generator

2013 Macgill-Ross MAC6000 Ground Heater w/ Generator

2013 Macgill-Ross MAC6000 Ground Heater

Hours: 3,922 Hours

Diesel Fired

635,000 BTU’s

Pintle Hitch

Onboard Isuzu Diesel Motor/Generator

-Fully enclosed

-Powers machine to make it useable on any jobsite

Up to 56 hours at 75% and 78 hours at 50% of run time

Up to 6,000 square feet (558 square meters) of coverage area

Flexible heat for any situation; the MAC6000 Hydronic Surface Heater

This unit is completely self-contained and mounted on a tandem axle trailer. It features 110% fluid containment and has six (6) 500 foot (153 meter) sections of ground hose for maximizing coverage options on every jobsite. The combustion chamber is 86% efficient and has an input of 630,000 BTU’s per hour (185 kW). The MAC6000 is comprised of rugged, heavy duty steel construction inside and out, with a powder coat exterior finish. This unit provides oversized access doors for service, maintenance, and operation. It also features user-friendly, PLC based push button controls for ease of use and accurate operation.

Engineered for reliable performance and trouble-free starts

Unit is fully functional and has just been serviced!

2020 Wacker Neuson E3000 Ground Heater w/ Generator

2020-Wacker-Neuson-E3000-Ground-Curing-Construction-Heating-Concrete-Curing-Ground-Heater-Generator

2020 Wacker Neuson E3000 Ground Heater w/ Generator

2020 Wacker Neuson E3000

Hours:1,083.2

Diesel Fired

385,000 BTU’s

2” Ball

Onboard 6Kw Kohler Diesel Generator

-Hours: 1,109.5

-Fully enclosed

-Powers machine to make it useable on any jobsite

Dual rear hose set up

One pump per hose loop means delivery of maximum Btu’s per hour.

Engineered for reliable performance and trouble-free starts

up to 140 hours of run time

the E3000 will provide maximum flow and ensure consistent heat delivery for thawing and curing applications.

The E3000 thaws or cures up to 6,000 sq. ft. With accessories this heater will cure up to 18,000 sq. ft. or provide 535,000 cu. ft. of dry heat at 83% efficiency, the highest in the industry.

With 3,000 ft. of hose and a hydraulic hose system, the E3000 allows for single person set-up and placement, for greater flexibility on all applications.

Positive displacement pump provides maximum flow and consistent heat delivery for thawing and curing.

Digital temperature controller with push button adjustment allows operators to easily adjust Heat Transfer Fluid (HTF) output temperature for all concrete curing applications.

Unit is fully functional and has just been serviced!