2013 Campo Ecoblaze Blaze Cube 1100 Indirect Fired Enclosed Self-Contained Mobile Construction Heater
2013 Campo Ecoblaze Blaze Cube 1100
Powered by onboard Kubota Diesel Generator
NO.1, NO.2, Kerosene, furnace oil fired
IDF Heater (Indirect Fired Heater)
Hours: 6,027
2x 510,000 BTU heaters
4x 12” Outlets
Self-Contained and enclosed
Unit was just serviced and ready to go to work!
2014 Campo Ecoblaze Blaze Cube 1100 Indirect Fired Enclosed Self-Contained Mobile Construction Heater
2014 Campo Ecoblaze Blaze Cube 1100
Powered by onboard Kubota Diesel Generator
NO.1, NO.2, Kerosene, furnace oil fired
IDF Heater (Indirect Fired Heater)
Hours: 7,060
2x 510,000 BTU heaters
4x 12” Outlets
Self-Contained and enclosed
Unit was just serviced and ready to go to work!
2013 Macgill-Ross MAC6000 Ground Heater w/ Generator
2013 Macgill-Ross MAC6000 Ground Heater
Hours: 3,922 Hours
Diesel Fired
635,000 BTU’s
Pintle Hitch
Onboard Isuzu Diesel Motor/Generator
-Fully enclosed
-Powers machine to make it useable on any jobsite
Up to 56 hours at 75% and 78 hours at 50% of run time
Up to 6,000 square feet (558 square meters) of coverage area
Flexible heat for any situation; the MAC6000 Hydronic Surface Heater
This unit is completely self-contained and mounted on a tandem axle trailer. It features 110% fluid containment and has six (6) 500 foot (153 meter) sections of ground hose for maximizing coverage options on every jobsite. The combustion chamber is 86% efficient and has an input of 630,000 BTU’s per hour (185 kW). The MAC6000 is comprised of rugged, heavy duty steel construction inside and out, with a powder coat exterior finish. This unit provides oversized access doors for service, maintenance, and operation. It also features user-friendly, PLC based push button controls for ease of use and accurate operation.
Engineered for reliable performance and trouble-free starts
Unit is fully functional and has just been serviced!
2014 MAC 800G Indirect Fired Enclosed Self-Contained Mobile Construction Heater
2014 MAC 800G
Powered by Isuzu Diesel
Diesel Fired
Hours: 6,636
800,000 BTU
2x 11” Outlet
2x 11″ Ducting included
Self-Contained and fully enclosed
IDF Heater (Indirect Fired Heater)
Air output volume: 3,900 Cubic Ft per minute
Unit is fully function and ready to go to work!
2014 MAC 800G Indirect Fired Enclosed Self-Contained Mobile Construction Heater
2014 MAC 800G
Powered by Isuzu Diesel
Diesel Fired
Hours: 2,001
800,000 BTU
2x 11” Outlet
2x 11″ Ducting included
Self-Contained and fully enclosed
IDF Heater (Indirect Fired Heater)
Air output volume: 3,900 Cubic Ft per minute
Unit is fully function and ready to go to work!
2010 MAC 800G Indirect Fired Enclosed Self-Contained Mobile Construction Heater
2010 MAC 800G
Powered by Kubota Diesel
Diesel Fired
Hours: 9,014
800,000 BTU
2x 11” Outlet
2x 11″ Ducting included
Self-Contained and fully enclosed
IDF Heater (Indirect Fired Heater)
Air output volume: 3,900 Cubic Ft per minute
Unit is fully function and ready to go to work!
2020 Wacker Neuson E3000 Ground Heater w/ Generator
2020 Wacker Neuson E3000
Hours:1,083.2
Diesel Fired
385,000 BTU’s
2” Ball
Onboard 6Kw Kohler Diesel Generator
-Hours: 1,109.5
-Fully enclosed
-Powers machine to make it useable on any jobsite
Dual rear hose set up
One pump per hose loop means delivery of maximum Btu’s per hour.
Engineered for reliable performance and trouble-free starts
up to 140 hours of run time
the E3000 will provide maximum flow and ensure consistent heat delivery for thawing and curing applications.
The E3000 thaws or cures up to 6,000 sq. ft. With accessories this heater will cure up to 18,000 sq. ft. or provide 535,000 cu. ft. of dry heat at 83% efficiency, the highest in the industry.
With 3,000 ft. of hose and a hydraulic hose system, the E3000 allows for single person set-up and placement, for greater flexibility on all applications.
Positive displacement pump provides maximum flow and consistent heat delivery for thawing and curing.
Digital temperature controller with push button adjustment allows operators to easily adjust Heat Transfer Fluid (HTF) output temperature for all concrete curing applications.
Unit is fully functional and has just been serviced!
2020 Wacker Neuson E3000 Ground Heater w/ Generator
2020 Wacker Neuson E3000
Hours:730
Diesel Fired
385,000 BTU’s
2” Ball
Onboard 6Kw Kohler Diesel Generator
-Hours: 856.7
-Fully enclosed
-Powers machine to make it useable on any jobsite
Dual rear hose set up
One pump per hose loop means delivery of maximum Btu’s per hour.
Engineered for reliable performance and trouble-free starts
up to 140 hours of run time
the E3000 will provide maximum flow and ensure consistent heat delivery for thawing and curing applications.
The E3000 thaws or cures up to 6,000 sq. ft. With accessories this heater will cure up to 18,000 sq. ft. or provide 535,000 cu. ft. of dry heat at 83% efficiency, the highest in the industry.
With 3,000 ft. of hose and a hydraulic hose system, the E3000 allows for single person set-up and placement, for greater flexibility on all applications.
Positive displacement pump provides maximum flow and consistent heat delivery for thawing and curing.
Digital temperature controller with push button adjustment allows operators to easily adjust Heat Transfer Fluid (HTF) output temperature for all concrete curing applications.
Unit is fully functional and has just been serviced!
2010 Dryair Greenthaw 600GTS Ground Heater w/ Generator
2010 Dryair 600GTS
Hours: 2,218
Diesel Fired
Pintle Hitch
Onboard 7KW Kubota Diesel Powered Whisper Watt Generator
-Fully Enclosed
-Powers machine to make it useable on any jobsite
-Phase: 1
-120/240
620k BTU Heater
4,000’ of hose
-Power Reel (In and out)
THAW AREA – 6,000 ft² (std), 11,200 ft² (w/acc)
CURE AREA – 8,000 ft² (std), 25,000 ft² (w/acc)
The large 620,000 BTU heater provides you with ample BTU’s for ground thaw, concrete cure & space or fluid heating applications
Patented Flow Reverser – Eliminates hot and cold zones in the thaw pattern
Reduces time & fuel costs by up to 50%
Consistent curing temperatures across the entire slab means the whole slab cures at the same rate
Patented Combustion Environment Control System preheats the fuel and air used for combustion
No need to bring it in to a heated shop before it goes out on the job. The preheater allows the unit to start & run even in sub 40 degree conditions
Industry leading multi-loop ground thaw set-up for job site flexibility and optimum fluid circulation & heat transfer
Manifold System allows for fan coils or heat exchangers to plug in for space heating or fluid heating
Unit is fully functional and ready to go to work!
2014 LD5030 Enclosed Ground Heater Construction Heater Concrete Curer w/ Generator
2014 Thor LD5030
Hours: 5,072
Boiler 329,000 BTU
Fuel Capacity 120 US gals
Heat Transfer Propylene Glycol/Water
Fluid Reservoir 78 US gals
Hose Length (3) 1000ft loops
Hose Rating 200 PSI
Electrical Requirements 30 amp, 120V
Trailer 6×12 Tandem Axel\
Onboard Multiquip DA-7000 Diesel Generator
The control panel features large, easy to use switches, digital supply and return temperature controls with warning and operation lights for all components. The entire system is protected by a ground fault interrupt breaker and is CSA certified for safety assurance.
Kubota Diesel
Hours: 5,224
7Kw
120v/240v
60hz
Single phase
Unit is fully functional and has just been fully serviced!
Ready to go to work!
Recent Comments