2021 Heat Wagon VG1000 1MIL BTU Indirect Fired Portable Heater

2021-Heat-Wagon-VG1000-1MIL-BTU-Indirect-Fired-Portable-Heater

2021 Heat Wagon VG1000 1MIL BTU Indirect Fired Portable Heater

2021 Heat Wagon VG1000

LP or Natural Gas Capable

Input: 1,000,000 BTU/Hr

Gas Consumption 11 GPH Propane/1000 CFH NG

Gas Connection 1-1/4” FNPT

Electrical: 240 Volts

Fan: 4,075 CFM 2.0” SP

Max Temp: 200°F

Remote Thermostat Controlled

Indoor/Outdoor

Clean Dry Heat

Duct size: 20″ diameter

Ductable to 200′

Transport Weight: 1,500lbs

Transport Dimensions: 120”x32”x55”

2021 Heat Wagon VG1000 1MIL BTU Indirect Fired Portable Heater

2021-Heat-Wagon-VG1000-1MIL-BTU-Indirect-Fired-Portable-Heater

2021 Heat Wagon VG1000 1MIL BTU Indirect Fired Portable Heater

2021 Heat Wagon VG1000

LP or Natural Gas Capable

Input: 1,000,000 BTU/Hr

Gas Consumption 11 GPH Propane/1000 CFH NG

Gas Connection 1-1/4” FNPT

Electrical: 240 Volts

Fan: 4,075 CFM 2.0” SP

Max Temp: 200°F

Remote Thermostat Controlled

Indoor/Outdoor

Clean Dry Heat

Duct size: 20″ diameter

Ductable to 200′

Transport Weight: 1,500lbs

Transport Dimensions: 120”x32”x55”

2021 Heat Wagon VG1000 1MIL BTU Indirect Fired Portable Heater

2021-Heat-Wagon-VG1000-1MIL-BTU-Indirect-Fired-Portable-Heater

2021 Heat Wagon VG1000 1MIL BTU Indirect Fired Portable Heater

2021 Heat Wagon VG1000

LP or Natural Gas Capable

Input: 1,000,000 BTU/Hr

Gas Consumption 11 GPH Propane/1000 CFH NG

Gas Connection 1-1/4” FNPT

Electrical: 240 Volts

Fan: 4,075 CFM 2.0” SP

Max Temp: 200°F

Remote Thermostat Controlled

Indoor/Outdoor

Clean Dry Heat

Duct size: 20″ diameter

Ductable to 200′

Transport Weight: 1,500lbs

Transport Dimensions: 120”x32”x55”

 

2004 Thawzall TCH150 Heatzone Ground Heater W/ Generator

New-Used-Equipment-Equipment-Dealer-Bucket Truck-Digger Derrick-Altec-Terex-Versalift-Forestry Equipment-Diesel-Freightliner-Kenworth-Peterbilt-Western Star-International-Peterbilt-Paccaar-Cummins-Maxxforce-Detriot Diesel-Turbo-Construction-Equipment-Ground-Heaters-Cranes-Boom-Trucks-Utility Trucks-Storm Trucks

2004 Thawzall TCH150 Heatzone Ground Heater W/ Generator

2004 Thawzall TCH150

Kubota Diesel Engine Powered/Genset

Hour Meter Reads: 12,412 Hours

150k BTU Heater

THAW frozen ground sq ft 1,200 – 2,400

CURE concrete sq ft 2,400 with accessories sq ft 6,000 max

FROST prevention sq ft 2,400 with accessories sq ft 10,800 max

HEAT buildings

Operating Range °F 180

Operating Pressure psi 1-5

Fuel Consumption (max) gph 1.0

Run Time days 4+

Pump Capacity gpm/gph 30/1800

DIMENSIONS & CAPACITIES:

L x W x H 161″ x 174″ x 79″

Weight w/fuel & fluid lbs 3,460

Fuel Capacity:102 Gallons

HTF (Heat Transfer Fluid) 56 Gallons

MISC. SPECIFICATIONS:

One – 1/2 hp Pump Closed Loop

Centrifugal Hose Length (2 zones x 600’) ft 1,200

Electrical, GFI 1) 20 amp x 120 vac

HTF Pumpability °F -80

Fuel Winter blend diesel or #1 fuel oil

2” Ball Hitch

Unit has been serviced and greased!

2015 Dryair Greenthaw 300GTS Ground Heater w/ Generator

New-Used-Equipment-Equipment-Dealer-Bucket Truck-Digger Derrick-Altec-Terex-Versalift-Forestry Equipment-Diesel-Freightliner-Kenworth-Peterbilt-Western Star-International-Peterbilt-Paccaar-Cummins-Maxxforce-Detriot Diesel-Turbo-Construction-Equipment-Ground-Heaters-Cranes-Boom-Trucks-Utility Trucks-Storm Trucks

2015 Dryair Greenthaw 300GTS Ground Heater w/ Generator
2015 Greenthaw Dryair 300GTS
Hours: 2,847
Pintle Hitch
301k BTU Heater
Fuel: Diesel Fuel/ #1 or #2 Heating Oil
Burner: Single stage
Input capacity: 301,000 BTU
Output max capacity: 228,000 BTU
Fuel Consumption (100% run time) 2.15 GPH
Maximum thawing capacity: 6,000 sq. ft
Maximum Curing Area: 12,040 sq. ft
Operating temp: 195 degrees Fahrenheit
Heating capacity – area: 433,154 cu. ft
Heat transfer fluid: nontoxic propylene glycol
Operating pressure: 35 PSI
Flow: 965 GPH
Power Hose Reel
Onboard Hose max: 3,000′
Fuel Capacity: 150 gallons
Onboard 6.5KW Diesel gl7000 Kubota Generator
-Fully Enclosed
-Powers machine to make it useable on any jobsite
-Phase: Single
-120/240
No need to bring the Greenthaw in to a heated shop before it goes out on jobsite! The preheater allows the unit to start and run in sub 40 degree conditions!
Unit was just serviced and greased an ready to work!

2011 Dryair Greenthaw 600GTS Ground Heater w/ Generator

New-Used-Equipment-Equipment-Dealer-Bucket Truck-Digger Derrick-Altec-Terex-Versalift-Forestry Equipment-Diesel-Freightliner-Kenworth-Peterbilt-Western Star-International-Peterbilt-Paccaar-Cummins-Maxxforce-Detriot Diesel-Turbo-Construction-Equipment-Ground-Heaters-Cranes-Boom-Trucks-Utility Trucks-Storm Trucks

2011 Dryair Greenthaw 600GTS Ground Heater w/ Generator

2011 Dryair 600GTS

Genset Hour Meter Reads: 309 Hours

Diesel Fired

2” Ball

Onboard 7KW Kubota Diesel Powered Whisper Watt Generator

-Fully Enclosed

-Powers machine to make it useable on any jobsite

-Phase: 1

-120/240

620k BTU Heater

Can Carry up to 4,000’ of Hose

-Power Reel (In and out)

THAW AREA – 6,000 ft² (std), 11,200 ft² (w/acc)

CURE AREA – 8,000 ft² (std), 25,000 ft² (w/acc)

The large 620,000 BTU heater provides you with ample BTU’s for ground thaw, concrete cure & space or fluid heating applications

Patented Flow Reverser  – Eliminates hot and cold zones in the thaw pattern

Reduces time & fuel costs by up to 50%

Consistent curing temperatures across the entire slab means the whole slab cures at the same rate

Patented Combustion Environment Control System preheats the fuel and air used for combustion

No need to bring it in to a heated shop before it goes out on the job.  The preheater allows the unit to start & run even in sub 40 degree conditions

Industry leading multi-loop ground thaw set-up for job site flexibility and optimum fluid circulation & heat transfer

Manifold System allows for fan coils or heat exchangers to plug in for space heating or fluid heating

Unit is fully functional and ready to go to work!